Data Diode Rugged 1Gbit SM
Fibersystem Rugged Data Diodes are designed to operate in extremely harsh environments and conditions. Enables unidirectional transfer of data over Fiber cable between two networks with hardware separation to guarantee security. This completely eliminates the risk for data flowing in false direction.
- Ruggedized for the tuffest environments
- One-way connection between two networks (also known as Simplex)
- Hardware based, no extra software needed. This completely eliminates the risk for data flowing in false direction
- Fiberoptical links for galvanic seperation between networks
- Data will be transparently forwarded
- No extra software needed when using one way compatible protocols, such as: UDP stream/broadcast, Syslog, NTP, SNMP traps
Versions of Data Diodes Rugged
- 100Mbit or 1Gbit
- TEMPEST Level A/ EMSEC/ RÖS U1
- Other versions see seperate Datasheet Data Diodes 50-800 System
Low pressure
Designed to operate in low pressure according to MIL-STD 810G test method 500.5 Procedure-I type B airtransport storage and for operation procedure –II type a)
High temperature
Designed to operate in high temperature according to MIL-STD 810G test method 501.5 Procedure -I (operation) level Hot dry +70°C and procedure-III (storage) Hot/dry (+71°C)
Low temperature
Designed to operate in low temperature according to MIL-STD 810G test method 502.5 Procedure -I (Storage) Cold (C2)-46°C and procedure -II(operation) Cold (C2)-40°C
Rain
Designed to operate in Rain according to MIL-STD 810G test method 506.5 Rain 506.4-I Outdoor, -II indoor with drop
Humidity
Designed to operate in Humidity according to MIL-STD 810G test method 507.4 procedure -I High RH (B2) 6 cycles
Salt fog
Designed to operate in Salt fog according to MIL-STD810G test method 509.5 with 5% concentration for 7 days
Vibrations
Designed to operate in Vibrations according to MIL-STD 810G test method 514.5 procedure-I and -II Operation category 14 and 20; transport category 4,5 and 10. (Shock 40g@11ms, Chock 75g@6ms)
Shock
Designed to operate in Shock according to MIL-STD 810G method 516.6 procedure -I (functional test for ground equipment) 3 shocks in each 6 directions
Water protected
Designed to be Water protected according to IPX5
Dust protected
Designed to be Dust protected according to IP4X
EMC protected
Designed to be EMC protected according to MIL-STD 461F method; RE102 level Navy Mobile & Army and CE102 level Basic curve
EMI protected
Designed to be EMI protected according to MIL-STD 461F method: RS103 level Army; CS101 level Curve#1; CS114 level Army; CS115 level Army and CS116 level Army
Galvanic/Electrical link
- Data speed 100Mbit or 1Gbit depending on model
Fiber optic links
- Data speed 100Mbit or 1Gbit depending on model
- Wavelength 850nm. Optional 1310nm.
- Fiber optical connector LC
- Fiber Multi mode 50/125μm or 62.5/125μm
- Optical system budget 13dB in 62.5/125μm. 9dB in 50/125μm fiber
- Typical distance 0 – 2km (3dB system margin for 50/125μm and 6dB for 62.5/125μm)
Environmental
- Temperature range -40 to + 70°C
Power Supply
- DC 10-32VDC, Max 10W. (Optional 18-75VDC)
- DC-connector 3 pin
Power Consumtion
- 2,5W
Regulatory compliance
- Safety: CE
- Environmental: Complies with appropriate requirements of RoHs and WEEE
MIL Standard
- MIL-STD 810G, MIL-STD 461F (Only 60-00-7132, 60-00-7444, 60-00-7133)
RÖS U1/TEMPEST Level A
- Class SS1 (Only 60-00-7132, 60-00-7444, 60-00-7133)
Dimensions and Weight
- 44 (H), 110(W), 227(D)mm/ 1.7(H), 4.3(W), 8.9(D)inch 1 HU high and ¼ 19inch wide
- 1.4kg/ 3.09lbs